Habib Arjmand Mazidi, Ph.D. profile photo

Habib Arjmand Mazidi, Ph.D.

Assistant Professor

  • Milwaukee WI UNITED STATES

Dr. Mazidi's areas of interest include sustainable energy strategies, building energy performances, and design lighting systems

Education, Licensure and Certification

B.S/M.Arch.

Architecture

Yazd University

2005

M.S.

Architectural Engineering

University of Kansas

2019

Ph.D.

Civil Engineering

University of Kansas

2023

Biography

Dr. Mazidi is an Assistant Professor in the Civil and Architectural Engineering and Construction Management Department at the Milwaukee School of Engineering.
He holds an integrated B.S./M.Arch degree in Architecture from Yazd University, as well as an M.S. in Architectural Engineering with a specialization in lighting design, and a Ph.D. in Civil Engineering/Architectural Engineering with a focus on building energy performance—both from the University of Kansas.
During his Ph.D. studies, Dr. Mazidi made significant contributions to a U.S. Department of Energy-funded project, conducting research on thermal storage materials, particularly phase change materials (PCMs).
In addition to his academic accomplishments, Dr. Mazidi has valuable industry experience as an architectural and lighting designer. His combined expertise as both an educator and a practitioner brings a unique, real-world perspective to his teaching and research.

Areas of Expertise

Sustainable Energy
Building Energy Performances
Thermal Energy Storage
Electrical Lighting Systems
Daylighting
Renewable Energy Systems

Accomplishments

Award of Best Luminaire Design, Emerging Professionals Competition, IES Kansas City, USA

2018

Education Trust Stipend Scholarship, IALD, USA

2018

Annual IES Conference Scholarship, Portland

2017

Affiliations

  • Architectural Engineering Institute (AEI): Member
  • Illuminating Engineering Society (IES) : Member
  • ASHRAE : Member

Languages

  • Persian

Social

Event and Speaking Appearances

Speaker

IES24 The Lighting Conference  New York, NY

2024-08-15

Speaker

2025 ASHRAE Winter Conference  Orlando, FL

2025-08-12

Teaching Areas

Building Energy Simulations

Building energy simulation, measurement, and benchmarking to support design and compliance with rating and labeling programs for commercial buildings.

Materials and Methods

A study of the properties of construction materials, their methods of manufacturing, and methods of construction.

Design of Lighting Systems

Building and site lighting through lighting principles, light sources, visual comfort, controls, daylighting, code compliance, and software-aided design.

Selected Publications

Comparative Analysis of Daylight Performance and Energy Efficiency of Milli Solar Blinds vs. Low-E Coated Glazing in Building Fenestration

IES 2024 Annual Conference Proceedings

Arjmand Mazidi, H.

2024-08-17

The role of fenestration systems in providing a well-lit environment is sometimes underestimated in building design when focusing on satisfying energy codes. While Low-E coated glazing windows typically meet energy requirements, they may negatively impact the illuminance levels of a space due to their generally lower visible transmittance (VT). Additionally, in most cold regions, solar heat gain is reduced by Low-E coated glazing systems during heating demand seasons.
In this computer simulation study using Radiance® and EnergyPlus® tools, a new fenestration system called Milli Solar Blinds (MSBs) is proposed and compared to a double-layer clear-glass window with 0.89 VT (used as the base case) and several Low-E coated windows in two climate zones: 4A (Baltimore, MD) and 2B (Phoenix, AZ), with south and west orientations. The MSBs system consists of milli-scale horizontal and vertical slats made of Low-E films placed in the gap between two clear-glass panes (10 mm gap). The size and angles of the slats were designed using the solar shading mask method.
Based on the results of this study, the MSBs demonstrated significant lighting performance and energy reduction effectiveness in south-facing orientations for both locations, exceeding the performance of Low-E windows by up to 10% in annual cooling energy savings, 37% in annual heating energy savings, 7% in annual lighting energy savings, and 6% in summer peak cooling and lighting demand. However, the illuminance outcomes for the west orientation were negatively affected due to the density of the horizontal and vertical slats in that direction.

Retrofit Solutions to Improve the Energy Performance of Existing Operational U.S Administrative Buildings

ASHRAE Transactions - 2025 Winter Conference, Orlando, FL, Vol. 131, Pt 1

Arjmand Mazidi, H., Wijesuriya, S., Anant Kishore, R., Booten, C., Medina, M.

2025-02-12

The U.S. building stock constructed before 1980 is aging and increasingly in need of retrofit measures to enhance thermal and energy performance. This study utilizes a highly detailed, time-resolved, calibrated, and validated whole-building model of an administrative building in the City of Wellington, Sumner County, Kansas, to evaluate various retrofit strategies and identify the most effective methods for improving energy efficiency. The rigorous calibration, exceeding traditional standards, was driven by the needs of a concurrent energy storage and grid resilience investigation requiring high model fidelity. The building, built prior to 1980 and subjected to several piecemeal renovations, exhibited issues such as high air leakage, complex air mixing between the plenum and conditioned space, heat stratification in the occupied zone during winter, and duct leakage into the plenum. Additionally, the oversized plenum with inadequate insulation contributed to significant heat loss.
The calibrated model, with a CVRMSE of 6.6% for natural gas and 6.7% for electricity, aligns well with ASHRAE Guideline 14 criteria and serves as the baseline for this analysis. The building's energy consumption exceeds median values for Zone 4A from the 2018 EIA CBECS Survey Data by approximately 17% for cooling electricity and 37% for heating natural gas. The study explored a series of retrofit scenarios in the whole-building model, with an early-stage combination of duct leakage correction and air-sealing measures yielding reductions of 10.8% in annual cooling electricity, 12.7% in demand, and 33.1% in natural gas consumption. Further parametric analysis of additional measures—such as plenum insulation, efficient windows, cool roofing, adjusted plenum depth, and HVAC heat exchangers—revealed that plenum insulation and heat exchanger improvements had the most significant impact on energy savings. The study demonstrates that a comprehensive combination of retrofit scenarios can achieve up to 43.5% savings in annual cooling energy and 49.7% in heating energy, with the potential for a 44.9% demand shift. These findings offer valuable insights into effective strategies for improving the energy performance of aging office buildings through targeted retrofitting.

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

Energy and Buildings

Wijesuriya, S., Arjmand Mazidi, H., Anant Kishore, R., Booten, C.

2025-03-01

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. This study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants’ comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23 °C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2 °C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

View more

Powered by