Education, Licensure and Certification (3)
Ph.D.: Electrical and Computer Engineering, University of Texas at Austin 2003
M.S.: Electrical Engineering, Universidade de Brasilia 2000
B.S.: Electrical and Electronic Engineering, Universidade Federal da Paraiba 1998
Biography
Dr. Icaro dos Santos is an Associate Professor in the Electrical, Computer and Biomedical Engineering department and has been a faculty member at MSOE since 2016.
Dr. Ícaro dos Santos is an accomplished biomedical engineer and academic with extensive experience in medical device innovation and strategic business planning. He holds a Ph.D. in Electrical and Computer Engineering from the University of Texas at Austin, where he specialized in cardiac ablation, and an MBA in Strategy from the University of Wisconsin.
Currently, Dr. dos Santos serves as an Associate Professor at the Milwaukee School of Engineering, where he develops curriculum and laboratory materials for Biomedical Engineering courses. He is also the Manager at VIKARE, leading the design and development of medical devices for CO2 management.
With a robust background in both academia and industry, Dr. dos Santos has held key positions such as Principal Research and Development Engineer at ComfortApnea and Chief Research Officer at Astus Medical Manufacturing. His work has led to several patents, including innovations in sleep apnea therapy and negative air pressure devices.
Dr. dos Santos is fluent in English and Portuguese and has a proven track record in obtaining FDA approvals, developing prototypes, and securing research grants. His contributions to the field are further evidenced by numerous journal and conference publications, as well as his leadership in various industry-funded projects.
In addition to his professional achievements, Dr. dos Santos has been recognized with multiple scholarships for high productivity in applied research and has played a pivotal role in advancing biomedical engineering education and research both in the United States and Brazil.
Areas of Expertise (5)
Simulink and Control Systems
Static Electricity
Artificial Intelligence
Biomedical Engineering
Analog Hardware
Accomplishments (2)
Scholarship for high productivity in applied research for the industry, CNPq, Brazil
2012
Scholarship for High Productivity in Applied Research for the Industry, Conselho Nacional de Desenvolvimento Científico e CNPq
2008
Languages (2)
- English
- Portuguese
Media Appearances (1)
Dr. Icaro dos Santos
MSOE News
2019-10-24
“I always enjoyed practical applications of electrical engineering in medical devices and wanted to share my enthusiasm and experience with students,” said dos Santos. He shares his passion of practical applications with students during lab. “My favorite part about being a professor is going to the lab and making things work!”
Teaching Areas (3)
Biomedical Instrumentation
To design and test medical instrumentation
Control Systems
To design medical device control systems
Biomedical Design
To design and test medical devices
Patents (1)
Sleep apnea therapy device that automatically adjusts the fraction of inspired carbon dioxide
US10231864B1
A comfortable device for treating sleep apnea incorporates a mask, a flexible hose and a chamber for collecting expired air containing CO2. A sensor detects apnea and a control system automatically adjusts the amount of rebreathed CO2 to minimize apnea and also minimize arousal.
Research Grants (4)
Grant
Ministry of Health- Brazil
2009 to 2015
Brazilian National Health Surveillance Agency
Agência Nacional de Vigilância Sanitária (ANVISA)
2012 to June 2015
Coordination for the Improvement of Higher Education Personnel
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
2010
National Council for Scientific and Technological Development
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
2003–2009
Selected Publications (5)
A Modeling Study on Inspired CO2 Rebreathing Device for Sleep Apnea Treatment by Means of CFD Analysis and Experiment
Journal of Medical and Biological EngineeringShokoueinejad, M., Pazouki, A., Levin, J., Wang, F., Fernandez, C., Rusk, S., dos Santos, Í., Mulchrone, A., Dempsey, J., Webster, J.G.,
2017 We present the device design, simulation, and measurement results of a therapy device that potentially prevents sleep apnea by slightly increasing inspired CO2 through added dead space (DS). The rationale for treatment of sleep apnea with CO2 manipulation is based on two recently reported premises: (i) preventing transient reductions in PaCO2 will prevent the patient from reaching their apneic threshold, thereby preventing “central” apnea and instabilities in respiratory motor output; and (ii) raising PaCO2 and end-tidal CO2, even by a minimal amount, provides a strong recruitment of upper airway dilator muscles, thereby preventing airway obstruction. We have also provided the simulation results, obtained from solving the Navier–Stokes (NS) equations within the device volume. Therein, the NS equations are coupled with a convection–diffusion equation that represents the transport of CO2 in the device, thus enabling the transient simulation of CO2 propagation. Using this procedure, a prototype of variable volume dead space reservoir device was designed. Volumetric factors influencing carbon dioxide increases in the added reservoir (open-ended DS) were investigated. The maximum/minimum amount of CO2 concentration were obtained for the maximum/minimum device volume; 3.4 and 2.4 mol/m3 for the DS volumes of 1.2 and 0.5 × 10−3 m3, respectively. In all case studies, the CO2 buildup reached a plateau after approximately 20 breathing cycles. The experimental measurement results are in agreement with the simulation and numerical results obtained using the proposed simplified modeling technique, with a maximum relative error of 3.5%.
Probabilistic Finite Element Analysis of Radiofrequency Liver Ablation Using the Unscented Transform
Physics in Medicine and BiologyDos Santos, I., Haemmerich, D., Schutt, D., da Rocha, A.F., Menezes, L.R.
2009 The main limitation of radiofrequency (RF) ablation numerical simulations reported in the literature is their failure to provide statistical results based on the statistical variability of tissue thermal-electrical parameters. This work developed an efficient probabilistic approach to hepatic RF ablation in order to statistically evaluate the effect of four thermal-electrical properties of liver tissue on the uncertainty of the ablation zone dimensions: thermal conductivity, specific heat, blood perfusion and electrical conductivity. A deterministic thermal-electrical finite element model of a monopolar electrode inserted in the liver was coupled with the unscented transform method in order to obtain coagulation zone confidence intervals, probability and cumulative density functions. The coagulation zone volume, diameter and length were 10.96 cm(3), 2.17 cm and 4.08 cm, respectively (P < 0.01). Furthermore, a probabilistic sensitivity analysis showed that perfusion and thermal conductivity account for >95% of the variability in coagulation zone volume, diameter and length.
A Surgical Device for Radiofrequency Ablation of Large Liver Tumors
Physiological MeasurementDos Santos, I., Correia, D., Soares, A.J.M., Góes, J.A., Da Rocha, A.F., Schutt, D., Haemmerich, D.
2008 Radiofrequency ablation has become an accepted treatment option of patients with primary and metastatic liver tumors. We propose an ablation electrode array consisting of 4–8 blade shaped electrodes arranged in a circular geometry for the treatment of large liver tumors. We developed a 3D code based on the finite difference method for evaluating the effect of different numbers of electrodes (4, 6 and 8) and electrode distance on lesion size. The configuration with six electrodes can ablate a volume of 70 × 70 × 40 mm3 in approximately 5 min, with tissue temperature above 50 °C throughout the treatment volume. We then performed an experimental study in polyacrylamide gel in order to validate the theoretical results. The average temperature error between the simulation and the experiment was 3.8% at the center of the electrode array. This study shows that the proposed device potentially allows more rapid treatment of large tumors than current radiofrequency ablation devices.
Effect Of Variable Heat Transfer Coefficient on Tissue Temperature Next to a Large Vessel During Radiofrequency Tumor Ablation
Biomedical Engineering Onlinedos Santos, I., Haemmerich, D., da Silva Pinheiro, C., da Rocha, A.F.
2008 One of the current shortcomings of radiofrequency (RF) tumor ablation is its limited performance in regions close to large blood vessels, resulting in high recurrence rates at these locations. Computer models have been used to determine tissue temperatures during tumor ablation procedures. To simulate large vessels, either constant wall temperature or constant convective heat transfer coefficient (h) have been assumed at the vessel surface to simulate convection. However, the actual distribution of the temperature on the vessel wall is non-uniform and time-varying, and this feature makes the convective coefficient variable.
In Vitro Measurements of Temperature-dependent Specific Heat of Liver Tissue
Medical Engineering & PhysicsHaemmerich, D., Dos Santos, I., Schutt, D.J., Webster, J.G., Mahvi, D.M.
2006 We measured the specific heat of liver tissue in vitro by uniformly heating liver samples between two electrodes. We insulated the samples by expanded polystyrene, and corrected for heat loss and water loss. The specific heat of the liver is temperature-dependent, and increases by 17% at 83.5 °C (p < 0.05), compared to temperatures below 65 °C. The average specific heat was 3411 J kg−1 K−1 at 25 °C, and 4187 J kg−1 K−1 at 83.5 °C. Water loss from the samples was significant above 70 °C, with ∼20% of reduction in sample mass at 90 °C.
Social